lcd.status 1374 ? bit
field
Returnsthe status of the con-
nected LCD, all in one 16-bit
word.
bit 0 = video status: High if sync
is detected on the video inter-
face.
bit 1 = backlight status: High if
backlight is on.
bit 2-7 = Column position cur-
rently being sensed.
bit 8-13 = Row position currently
being sensed.
bit 14 = Voltage under limit: High
if the ADC reading is outside the
limits set in the chip. Limits are
set at startup to alert below 22v.
bit 15 = 1 if the tile is connected.
If tile is disconnected, all other
fields should be ignored.
69
lcd.vertial resolution 1126
70
lcd.voltage 1396 ? 0-2600
Returns the voltage read by the
attached LCD. Values below 22v
is cause for concern. Value is
multiplied by 100 to give hun-
dredths precision. Returns NAK
if no LCD is connected.